In vitro comparison of primary stability of two implant designs in D3 bone
2016
Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…
Comparison of implant primary stability between maxillary edentulous ridges receiving intramembranous origin block grafts
2012
Purpose: The purposes of the present study were: to compare the resonance frequency analysis (RFA) values of implant placed in either ramus or calvaria block grafts; and to determine if implant diameter influences RFA implant stability quotient (ISQ) value. Material and Methods: This was a retrospective study that included 16 consecutives healthy patients treated with autogenous onlay block grafts for horizontal bone reconstruction in maxilla. Ten ramus and ten calvaria block graft treated patients were selected and compared. Results: Totally, 59 implants were placed, 35 (59.3%) were placed on the calvaria bone grafts and the remaining 24 (40.7%) were on the ramus bone graft. Of all the imp…
Resonance frequency analysis after the placement of 133 dental implants
2006
Introducción: La estabilidad primaria del implante dental está relacionada con el hueso que se encuentra en contacto con él y se puede medir mediante el análisis de frecuencia de resonancia. Material y métodos: En 133 implantes (62 en maxilar y 71 en mandíbula) se midió la frecuencia de resonancia y la fuerza de inserción para conocer la estabilidad de los implantes el día de la cirugía, y estudiar su relación con distintas variables. Resultados: El cociente de estabilidad del implante obtenido el día de la cirugía fue de 62’1 y el de la fuerza de inserción fue de 35’7 Nw. La fuerza de inserción fue proporcional al análisis de la frecuencia de resonancia, a mayor fuerza de inserción mayor c…
Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomize…
2019
Background The aim of the present prospective clinical study is to compare the stability of the implant-bone interface by the ISQ quotient and marginal bone loss (MBL) rate during one year of follow-up in four system implants with the same surface and different design. Material and Methods Prospective randomized clinical trial of 21 patients in which four implant systems with the same surface and different design were placed. Patients were treated by the same operator following a similar surgical protocol with submerged technique. The second surgery to perform the prosthesis was performed at 3 months. All patients went to their review at 6 months and a year. A periapical radiograph for cres…
Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible.
2010
Background: Dental primary implant stability is considered essential in the success of the osseointegration process. The recent advent of the resonance frequency analysis (RFA) seems to effectively measure primary implant stability, although its relationship with implant survival has to be further established. Patients and Methods: Seventy patients with complete mandibular edentulism underwent dental implant rehabilitation by means of the placement of 68 dental implants within the interforaminal region and subsequent placement of an overdenture. Primary implant stability was measured by means of RFA and it was expressed in terms of imPrimary implant stability was measured by means of RFA an…
Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis
2015
Background This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). Material and Methods Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant s…
Repeatability of the resonance frequency analysis values in implants with a new technology
2019
Background Assess the reliability (by means of reproducibility and repeatability) of the PenguinRFA system, analyse the ISQ values of different implant types and correlate the ISQ with the insertion torque during the placement of the implant. Material and Methods 120 rough surface implants were placed in bovine bone (type II and III). The implants were divided into groups, according to its design. Once the implants were in place, the exact insertion torque was registered. Then, primary stability was measured by means of the resonance frequency analysis with the PenguinRFA and the Osstell ISQ devices. In each implant two transducers of each device were used. Three measurements were obtained …
Relation between bone quality values from ultrasound transmission velocity and implant stability parameters--an ex vivo study.
2011
Aim The objective of this study was to determine the relationship between bone qualities measured by ultrasound transmission velocity (UTV) and primary implant stability parameters measured by radiofrequency analysis (RFA) and push-out test (POT) in an ex-vivo model. Materials and methods Three blocks of fresh porcine bone samples were obtained from different anatomic regions, correlating to cortical, mixed and cancellous bone. Mechanical bone qualities of these samples were measured using UTV (expressed in m/s) prior to implantation. Three similar implants (4.1 × 11 mm, AstraTech OS) were inserted into each of the procured bone blocks. The evaluation of implant-bone interface stability was…
The effects of surgical preparation techniques and implant macro-geometry on primary stability : an in vitro study
2016
Background The attainment of a good primary stability is a necessary condition to ensure the success of osseointegration in implantology. In type IV cancellous bone, however, it is possible that a reduced primary stability can lead to an increased rate of failure. The aim of this study was therefore to determine, with the help of the resonance frequency (Osstell mentor), which technique of implant site preparation (piezo surgery, conventional, under-preparation, bone compaction, osteodistraction) and macro-geometry is able to improve implant stability in type IV cancellous bone. Material and Methods 10 pig ribs were prepared with a surgical pre-drilled guide, calibrated for a correct implan…
Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants
2014
Background To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. Purpose This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Materials and Methods Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediatel…